Industrial monitoring and control / Automation - I/O over network, USB or serial

Menu

Industrial monitoring and control / Automation - I/O over network, USB or serial

In this category you will find our analog and digital I / O modules. And a lot of other things including temperature sensors, Smart I / O modules, PLC and protocol converters. See blah. our 3 channel Quadrature counter with encoder for measuring eg. distance traveled.

Industrial monitoring and control / Automation - I/O over network, USB or serial
There are 266 products.
Modbus I/O Module with 8 x Digital Input Wet / Dry, 8 x Digital Output, with P2P

Modbus / TCP I / O module with built-in Web server
Modbus / TCP and Modbus / UDP protocols
2 x RJ45 Ethernet switch to Daisy-Chain topology
Dual Watchdog
Operating temperature range: - 25 to + 75 ° C
I / O Pair connection - Ingang refles in the second's exit
8 x Digital input: Wet (Apply Volt), Dry (Contact) - Digital Input: 0 - + 50CDC or Open / GND
8 x Digital Outout, Open Collector 0 - 40VDC / 650MA
Dimensions: 76 mm x 120 mm x 38 mm
Supply voltage: 12 - 48vdc, 4 watt
your bracket Wall mounting

2,982.00 kr
Varenummer ETH-MOD8I8O
Ethernet based module with MODBUS TCP/IP with 2 x digital input 2 x power relay

Ethernet I/O module Modbus/TCP / UDP slave
1 x RJ45 Ethernet
Redundant Power Supply
Protocol: TCP, UDP, HTTP, DHCP, BOOTP and TFTP
Web configuration and firmware update via Ethernet
2 x digital input (Wet - volts supplied)
2 x Relay, COM, NO - 250VAC 5A, 30VDC 5A
Avoid inductive load to relay contacts
With locked DI and 32-bit 3.5kHz counter
With I/O pair - input is mirrored in the other's output
Dual-watchdog with Power-on-safe value
Supply voltage: 12 - 48VDC, 1.7 Watt
Dimensions: 98 x 52 x 27 mm
Operating temperature: -25 - +75°C

972.00 kr
Varenummer ETH-MOD2I2R-I
Physically in stock
Fjernkontrol over netværk. 8 x kraftige relæer, 8 digitale indgange. Til temperatur- og fugtmåler

8 Potential-free relay outputs - 230Vac / 16 A, 24VDC / 10 A
Relay outputs are individually via HTTPS, SNMP or Command
Startup delay from 0 to 9999 seconds. Adjusted individually
Inrush Delay is set to 1 second
Programmable on / off sequence
Activating relays can be controlled from sensor or inputs
8 channel watchdog via ICMP / TCP Ping
8 signal entrances From NO and NC units, door contacts, etc.
Entrance to sensors Temperature, humidity and air pressure
Messages via e-mail, Sylog and SNMP Trap MQTT
Depending on thresholds for sensor measurement and signal input
LED display for overall power, IP address, sensor data and error reports
Android app and iOS app
DIN bracket

Call +45 56 66 20 20 for price
Varenummer ETHIO8I8PR-SENS
I/O Module with Wet and Dry contact

Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ + 75 ° C
I/O Pair - Input Mirrors at the second's output
8 x Digital input (counter): 0 - + 50VDC (500Hz) - Wet / Dry
8 x Digital output: Open Collector 0 - + 40VDC / 650MA per Ch 
2 x RJ45 Ethernet - Daisy Chain
Supply voltage: POE or 12 - 48VDC / 4Watt

3,077.00 kr
Varenummer ETHIO8I8O-P2I+
Physically in stock
8 x analog høj spænding indgange 16bit, 4 x digital udgang til LAN

Ethernet I/O module for the measurement of analog high-voltage differential inputs
8 x Analog input: +/-50V, +/-150V
4 x Digital output - Isolated Open Collector, max. 50VDC, 700mA per channel
16bit solution
Sample frequency: Normal mode 10 samples per second
Sample frequency fixed mode: 50 samples per second
Supports MODBUS TCP and UDP
Integrated Web Server - access with ID, password and IP filter
Power up and safe levels can be programmed
2 x RJ45 10 / 100Mbit ports - daisy-chain
Pair-connection - mirror one input to others output
Supply voltage: 12 - 48VDC 4,2Watt
Dimensions: 120 x 76 x 38 mm
Housing: plastic with DIN bracket

Call +45 56 66 20 20 for price
Varenummer ETHIO8AI4O-2-I
High Speed ​​8 analog inputs 200 kHz sample rate, 16-bit,

8 single ended input +/- 10V analog, +/- 5V
200kS / s (200 kHz) for each channel sampling rate
FIFO 2000 is sampled - the memory of 30 million data samples
16bit solution
Trigger mode: SW, Ext. clock, digital falling edge (post, pre, delay), analog
1 x 32-bit counter, max. 30 kHz
4 x digital input (wet) up to + 30VDC
4 x digital output (Open Collector) up to + 30VDC, 100mA
Overload protection up to 1.3A
1 x Ethernet port RJ45
Security: ID, password and IP filter
Powered by the PoE or 12 - 48VDC, 2,6W
Dimensions: 120 x 76 x 38 mm
Housing: Metal, with DIN bracket
Operating temperature: -25 - + 75 ° C

6,347.00 kr
Varenummer ETHIO8AI8IO-P-I
I / O module with 3 x AI, 6 x DI, 3 x relay to the LAN. Modbus TCP / UDP. Pair-compound

Built-in Web server
Web HMI
2 x RJ45 - Daisy Chain
Modbus TCP and Modbus UDP protocols
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ +75 ° C
I / O connection input pair is mirrored to the other's output
3 x Analog input +/- 10VDC, 0 - 20mA (differential)
6 x Digital input with counter
3 x Relay outputs COM, NO

3,873.00 kr
Varenummer ETHIO3AI6DI3R-I
Physically in stock
ICPDAS PETL-7060 is a Modbus module with 6 powerful relays, 6 digital input over Ethernet TCP/IP supplied from PoE

Modbus TCP Slave Module LAN or Internet
6 x Relay, End Contact 250VAC / 5A, 30VDC / 5A
Avoid inductive load
6 x Digital input. High is 10 - 50V
supply via PoE or 12 - 48VDC
is with I / O Pair Connection - Input is mirrored to exit.
with important "Sale Setting" which sets relays as desired
watchdog which sets relays in "Safe Setting" in error detection
Dim: 123 x 72 x 35 mm
built-in your bracket

1,663.00 kr
Varenummer ETH-MOD6I6R-P-I
Physically in stock
11 x Power Relay Module for Ethernet / MODBUS with PoE. 2 LAN ports

Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
2-port Ethernet switch for daisy-chain topology
Double watchdog
Wide operating temperature range: -25 ~ + 75 ° C
I / O pair connection. Mirrors the input to output
Built-in I / O to 11 x Power relay: 250VAC / 24VDC 5A
Supply voltage: 10 - 30VDC
PoE voltage is not fed to the LAN port 2
DIN mount

2,752.00 kr
Varenummer ETHIO11PR-P2I
8 x PhotoMOS relay output - not wear out, 60VDC 1A, 1 x RJ45 Ethernet. Modbus

The Web server
WEB HMI
Modbus TCP / UDP Modbus
Dual Watchdog
Operating temperature: -25 ~ +75°C
I/O Paie connection - input is mirrored to the other's output
8 x PhotoMOS relay (solid state) COM NO
Relay contact voltage: max 60VDC
Relay contact current: max. 1A
Switching times: on: 5ms, off: 0.3ms
Optical isolation to 3000 Vrms
Supply voltage: 10 - 30VDC / 3watt

2,056.00 kr
Varenummer ETHIO8PR-I
Digital inputs 8 x Wet 0 - + 50VDC 500Hz, 8 x Digital output (OC) + 40VDC 650mA, 1 x RJ45, Modbus

Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ + 75 ° C
I/O Pair connection - the input is mirrored in the other's output
8 x Digital input (count): 0 - + 50VDC (500Hz)
8 x Digital Outputs: Open Collector 0 - + 40VDC / 650mA per output
| 1 x RJ45 Ethernet
Power supply: PoE or 10 - 30VDC / 3watt

2,208.00 kr
Varenummer ETHIO8I8O-P-I
Digital inputs 8 x Wet 0 - + 50VDC 500Hz, 8 x Digital output (OC) + 40VDC 650mA, 2 x RJ45, Modbus

Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ + 75 ° C
I/O Pair connection - input is mirrored in the other's output
8 x Digital input (count): 0 - + 50VDC (500Hz)
8 x Digital Outputs: Open Collector 0 - + 40VDC / 650mA per output
2 x RJ45 Ethernet - Daisy chain
Power supply: PoE or 10 - 30VDC / 3watt
PoE fed NOT proceed to the next module - only data

2,861.00 kr
Varenummer ETHIO8I8O-P2I