Previous
Next

16 x voltage measurement via USB +/- 5V, 12bit, 1 x analog out, 4 x DI, 4 x DO

1,165.00 kr
Ekskl. moms

16 analog inputs via USB port, 10-100S / S
Resolution: 12 bit
Sample-speed: 10Hz per channel
1 Analog output +/- 5V
4 digital outputs TTL ( CMOS
4 digital inputs TTL / CMOS
Power supplied from the USB port
DAQ Software: Purchase NextView

Get Volume Offer
close

Get Volume Offer

 
file_download DOWNLOADS
Ask a question
close

Stil et spørgsmål

 

Specifications

Digital I/O 4 TTL indgange og 4 TTL udgange
Hastighed Op til 100 dataoverførsler per sekund. En dataoverførsel omfatter data fra alle 16 kanaler. Hastigheden er systemafhængig
Indgang 16 stk. ”Single ended”
Indgangsimpedans 1 MΩ
Kabel USB 2.0 og tidligere, 1,1 m langt
Måleområde ±5 V
Nøjagtighed ±5 mV (Abs.)
Opløsning 12 bit (2,5 mV/bit)
Software Leveres med "Active-X" drivere til Windows XP, Win7 og Win8 samt demo­software, der beskriver brugen af ”Active-X” driveren til Visual Basic, Delphi og C++. Software til ”live” målinger medfølger
Stik Alle indgange via DB37 hunstik
Strømforbrug Typisk 100 mA - forsynes via USB porten
Udgange 1 stk.12 bit ”Single ended”

Measurement and control simple. USB-AD16S12+ is USB data collection system ideal for universal applications and because of the small size perfectly suitable for mobile use - just connect and get started! Extra small. Extra red. The unique idea of ​​USB-AD16S12 + placed in D-sub housing is optimal for fieldwork.
Digital modes are recorded or controlled at 4 digital inputs and outputs each. Digital inputs are sampled time synchronously with analog inputs.
The device is supplied with power via USB interface. This reduces the cabling effort to a minimum and makes mobile measurements much easier.
The data collection system can be used under Windows® XP / 7/8/10 as well as under Mac OS X, free BSD and Linux.
Complete software for installation and programming USB-AD16S12+ is free. NEXTVIEW®. Try for free.
The DAQ system is supported by NEXTVIEW®, software for data collection and analysis.
A fully functional 14-day sample is included in the delivery to the test directly functionality of USB-AD16S12+.